The Sky's The Limit?

Tom Roche, Secretary of the Business Sprinkler Alliance.

This week has been full of conversations with different people across the built environment but one thing caught my attention: the scale of logistics buildings. In particular, there's renewed momentum behind designs of sheds that exceed 18m in height. Storage arrays on this scale are truly challenging but do we all understand what those challenges are?

Over my career, logistics buildings have been growing in footprint and in height. The days of the 10,000m2 warehouse with a height approaching 12m are a distant memory along with the vision of a fleet of tall slender automated warehouses exceeding 20m in height. However, as the scale of warehouses has grown, the understanding of fire protection challenges and the relevant regulatory guidance has often lagged behind.

Take regulatory guidance in England as an example. This week I heard a discussion about new projects where the steel portal frames had a 'haunch' height of 18m. The haunch typically signals the usable free height of the building, so what surprised me was how many people were unaware the regulatory guidance sets an 18m ceiling height for a storage building without sprinklers. The buildings being discussed would all exceed that limit. So, if used as a warehouse, the guidance would trigger a sprinkler requirement, with significant consequences for structural loadings and fit out. Given the limited demand for factory buildings at this height, it is clear the main market for these buildings is warehouse use.

I'll concede that Table 8.1 in Volume 2 of Approved Document B (ADB) takes a bit of studying but it has been in place for nearly 20 years. The table (see image) is confusing because it uses two different height-based metrics, each defined differently, in the same table. But read carefully and the limits are clear. My prior assumption was that many buildings stayed below the 15m haunch height to ensure they did not breach this 18m ceiling limit and trigger the sprinkler requirement.

-- Advertisement --
hss

It is important to note the trigger is not related to a volume or compartment size. Compartmentation does not deal with the height issue and it is also technically demanding to deliver in steel portal frame structures.

There are limits to fire protection

In the same conversation, I found myself explaining that current standards for active fire protection did not include 'ceiling-only' solutions for warehouses at 15m let alone such a higher building height. To be clear: those operating storage buildings would prefer ceiling-only sprinklers as a solution as it gives them more freedom in how they configure their storage. Traditionally, protecting open-rack storage structures has required a combination of ceiling sprinklers and in-rack sprinklers, quite literally sprinklers running within the racking. Obviously, this can limit the flexibility of storage arrangements.

From a fire behaviour perspective, a modern storage array is an ideal configuration for rapid fire growth. Fires in such storage arrays quickly become impossible to fight with manual means alone and often the fire will be too large before a fire service can intervene.

If the outcome is to protect the array then active fire protection is needed. To design such a scheme takes a careful consideration of what commodities are stored, how they are stored, any obstructions within the racking systems or indeed near to the sprinkler heads themselves. To appreciate the challenge, all of that then has to be coupled to a hydraulic design capable of delivering the right quantity of water quickly enough to suppress or control the fire.

Large-scale fire testing and research shows that it can be achieved using larger orifice sprinklers delivering substantial amounts of water. However, the research into ceiling-only sprinkler system designs mean that there are height limits. For certain types of storage, there are no designs at a ceiling height above 15m and for others the limit is closer to 12.5m. These heights are well below the ceiling heights proposed for a number of speculative builds.

Similarly low levels of storage in a tall building are equally challenging to active fire protection. It takes time for the fire to cause the sprinklers to operate and when they do, more are needed. The options to deal with this are to significantly restrict the levels of storage and spread them out. If the stated aim of the project is a warehouse it is a bit of challenge.

The consequences of higher buildings is that they will require specific automatic sprinkler designs to protect them. Occupiers will be faced with decisions over layouts and perhaps compromises over their storage arrangements. If the structural design loads for the fire protection are not considered there may well be a clash with the ability to place active fire protection in the building in the first place. The industry may feel that the sky’s the limit, but our regulatory guidance and fire-protection capability needs to be considered in these buildings. We can’t afford to allow ignorance to define a fleet of buildings that cannot be properly protected, leaving them as stranded assets or even worse compromising the safety of both occupants and firefighters.

For more information about the Business Sprinkler Alliance visit www.business-sprinkler-alliance.org.

Latest Construction News

24/07/2026
Planning approval has been granted for the redevelopment of the Crystal Palace National Sports Centre (CPNSC), marking a major milestone in securing the long-term future of one of the UK's most significant sporting venues. The decision allows the project to move forward to the next phase, creating
Read More
24/07/2026
Designer Group has been appointed to carry out the mechanical and electrical (M&E) works for the redevelopment of West One in London, a major refurbishment and rebuild located above Bond Street Underground station. Originally developed in the late 1970s, the existing West One Shopping Centre is bei
Read More
24/07/2026
The London Irish Centre has appointed Sisk, one of Ireland and Britain's leading construction firms, as the main contractor for the £36–£38 million transformation of its home at 50–52 Camden Square. Work is due to start in early 2027 and the centre is planned to reopen in Q1 2029, marking a major s
Read More
24/07/2026
Network Rail has confirmed that Botley Road in Oxford will remain closed beyond the end of August, delaying the previously planned reopening agreed when the programme was revised in January 2025 to prioritise getting traffic moving again. During recent drainage excavation for the new road layout, t
Read More
24/07/2026
Network Rail and The Arch Company have agreed a multi-million-pound transaction to transfer a selection of London property assets into Arch Co's ownership, marking a further milestone in their ongoing partnership. The package comprises a mix of railway arches and other investment properties — inclu
Read More
24/07/2026
More than 100 builders came together in Oxfordshire for the FMB's National Conference, which doubled as a milestone celebration of the Federation's 85 years supporting the trade. Staged on 9–10 July at the Oxford Belfry Hotel & Spa, the event welcomed 156 delegates for a Business Conference under t
Read More
24/07/2026
Established in 1996, The Access Flooring Company—distinguished from copycat businesses—marks three decades of excellence by reinforcing its position as the UK's premier specialist in raised access flooring, raised floor configurations, and advanced pedestal floor system technologies. Marking its la
Read More
24/07/2026
NFRC is urging members to help shape a new Government strategy for built environment professions, as the sector adjusts to the Building Safety Regime and renewed expectations on competence, professionalism and accountability. NFRC recently took part in a Build UK forum with the Building Professions
Read More
24/07/2026
Fire safety in homes and buildings is under closer scrutiny than ever. Whether you’re replacing a door, adding a glazed screen or partitioning a space, using the correct fire-rated glass is essential. The Glass Shop Online supply certified fire-rated glass and help customers navigate the requiremen
Read More
23/07/2026
Mace Consult has been appointed across six lots of Transport for London's (TfL) Professional Services Framework 3 (PSF3), strengthening a long-running collaboration and positioning the firm as a leading delivery partner on major infrastructure across the capital. Under the framework, Mace Consult w
Read More